UltraBreeze: Testing the Gen1 Motor
Test the motor on a Gen1 UltraBreeze from inside the attic. Gen3 fans test at the plug instead: see UltraBreeze: Testing the Motor (Gen3).
Tools
- 1/8 in. Allen key
- 7/16 in. deep-well socket and ratchet
- 9-volt battery
- About 2 ft. of 22 AWG wire, red and black
Steps
- Unplug the thermal: find the plug hanging from the base of the fan and pull the two black connectors apart. This cuts the solar power to the fan. Pull on the connectors, not the wires.
- Loosen the 1/8 in. Allen screw on the blade's hub and pull the blade off carefully. A bent blade makes the fan shake.
- Pull the black and white wires off the motor. Note which terminal each one was on.
- Attach the black wire to the battery's negative (−) terminal and the red wire to the positive (+) terminal.
- Touch the red wire to the motor's red post and the black wire to the black post.
- If the motor spins, it's good. If it doesn't, contact us.
- Reconnect the black and white wires to their original terminals and make sure they're snug.
- Slide the blade back on with the Allen screw on the flat side of the shaft, hub flush with the end of the shaft, and tighten.
- Make sure nothing is in the blade's way, then plug the thermal back in. Push the connectors together until no metal shows between them.
Need help? Contact UltraBreeze technical support at support@atticbreeze.com or (254) 865-9999, Monday through Friday, 8 AM to 5 PM Central.